Results - Method DevelopmentSeneca Babcock ESI Program
GC-MS Method for VOC’s
- Adapted T01/T02
- calibrated with VOC/Water Standard
- sixty compounds at 8ppm
- detected 27 compounds
- Tested Samplers in Lab with Benzene Toluene Exposure - detected both.
Formaldehyde NIOSH Method